Basic Info.
Trademark
HZT/neutral/ OEM customized
Specification
298*148*148mm
Product Description
Wholesale Price Outdoor Waterproof 500W Rechargeable Battery Mobile Phone Charger Portable Power Station
- Applications:
Occation: Outdoor Activities, Home Backup, Emergency Power Supply, Camping, Medical Rescue; Outdoor Photography, etc
Home: TV, Standing Fan, Laptop, Smartphones, Tablets
Outdoor: DC Fan, DC LED Lights, Small Fridge
Digital electronic products: Projectors, Camera, Small Blenders, Drone
Medical Rescue:Breathing machine, CPAP
Camping:Camping Lights, Car Vacuums, Car Rice Cooker, Car Air Purifier
Three charge models
Application
Package
Portable power station*1, AC Adapter*1, User Manual*1
1.Scope:
This product specification applies to the lithium ion battery.Please contact us coordination with the settlement if you have any questions.
2.Type
2.1 Battery Type: TH01 14.8V32AH 500W/460WH
2.2 Cell Type: INR16850 3.7V 3200mAh
2.3 The products of all materials are in compliance with ROHS requirements.
3.General Performance
Item | Specifications | Remark |
3.01 Typical Capacity | 32Ah | Standard charge & Standard discharge / standard charge and discharge |
3.02 Min Capacity | 32Ah |
3.03 Nominal Voltage | 14.8V | / |
3.04 Under Discharge Voltage | 12V | |
3.05 Limited charge voltage | 16.8V | / |
3.06 Standard Charge method | 0.2C CC charge to 16.8V, then CV to 0.02C cut off | 23±2ºC |
3.07 Standard Discharge method | 0.2C CC Discharge to 12V | 23±2ºC |
3.08 Max. Charge Current | 0.15C | 15-45ºC |
3.09 Max. Discharge Current | 1.0C | 15-60ºC |
3.10 AC Output AC | 220V/500W | |
3.11 USB Output USB | 5V2.4A/QC 3.0 | QC 3.0:5V/3A,9V/2A,12V/1.5A |
3.12 Type-C Output Type-C | 5V/3A,9V/2A,12V/1.5A | |
3.13 Cigarette lighter | 12V/10A | |
3.14 DC Output | 12V/8A | |
3.15 Illuminating lamp | | Lighting available at night |
3.16 Display Screen | Display power percentage/AC & DC power percentage on/off status | |
3.17 AC/DC Output Button AC/DC | Control AC/DC output | |
3.18 Charging Interface | DC5521 female | |
3.19 Operating Temperature and Humidity Range |
Charge Temperature: 0ºC~45ºC Relative Humidity: 45-85%RH
DischargeTemperature: -10ºC~60ºC Relative Humidity: 45-85%RH | 0ºC~15ºC: Charge Current Max. 0.2C Charge Voltage Max. 16.8V 15ºC~45ºC: Charge Current Max. 1.0C Charge Voltage Max. 16.8V 16.8V |
3.20 Battery Resistance | <=50mΩ | AC Impedance 1kHz |
3.21 Weight | 4.2kg | |
3.22 Dimensions | Max:308x148x148mm | |
3.23 Storage Environment | Less than 1 month | -10°C ~ +45°C,90%RH Max |
Less than 12 month | -10°C ~+35°C,85%RH Max |
Long Time Storage | The capacity for a long time storage shall be 60~70% range |
Humidity | 60%±20% |
3.24 Capacity of shipment | 50% | |
4 Electrochemical Characteristic 4.1 Cycle life | Charge cell with 0.2C to 16.8V then CV to 0.02C cut off; Discharge cell with 0.2C until cell voltage reaches 12V. Repeat to 500 cycles, record remained capacity of 500th cycle. | Capacity Retention ≥80% of Cmin.. |
4.2 Self-Discharge | After the standard charging, storied the cells under the condition as ambient temperature 23±2 °C for 30 days, then measured the capacity with 0.2C till 12V at 23±2 °C as residual capacity. | Residual Capacity ≥85% Cmin /
|
5 Environment Characteristic 5.1Constant temperatureand constant humidity test | After Standard Charging, test condition: Temperature:40±5ºC Relative Humidity:90~95%RH Storage Time:48 hours Then return to room temperature for 2 hours,Then 0.2C discharged to 12V. | No explosion No fire No leakage Residual capacity ≥ 60% initial capacity |
5.2 Vibration test | A cell after standard charging and then vibrated for 90 minutes for each of the three mutually perpendicular planes with total excursion of 0.8mm and with frequency of 10 Hz to 55 Hz. | No explosion, no fire no leakage . |
6 . Safety Test Test Item | Test Method | Criteria |
6.1 Heating Test | Acell after standard charging, is to be put into an hot box. The temperature of the oven is to be raised at a rate of 5 ±2°C per minute to a temperature of 130 ±2°C and remain for 30 minutes. | No explosion No fire Temperature≤150ºC |
6.2 Overcharge protection | After the battery is fully charged, use constant current constant voltage source to continue to load the battery 8h, constant current constant voltage source voltage is set to 2 times the nominal voltage, the current is set to 2.0C external current | No fire, no smoking ,no explosion. The over charge protection function should be started. |
6.3 Over discharge testing | At standard testing condition,the cells be discharge to 12V according to the requirements of standard discharge, then connect with external load of 30 ohm for 24 hours. | No fire, no smoking ,no explosion. The over charge discharge function should be started. |
6.4 Short-circuit Test | Acell after standard charging, is to be short-circuited by connecting the positive and negative terminals of the cell with a circuit load having a resistance load of 80 ±20mΩ. When the cell temperature falls 20% lower than the peak or last 24h, stop testing. | No explosion No fire |
7.Testing conditions Unless otherwise specified, all tests stated in this product specifications Should be conducted under the following atmosphere conditions:Temperature:21ºC~25ºCRelative humidity:45~75%Atmospheric pressure: 86kpa~106kpa8. CAUTIONS IN USE 8.1 To ensure proper use of the battery please read the manual carefully before using it. Handling- Do not expose to, dispose of the battery in fire.
- Do not put the battery in a charger or equipment with wrong terminals connected.
- Avoid shorting the battery
- Avoid excessive physical shock or vibration.
- Do not disassemble or deform the battery.
- Do not immerse in water.
- Do not use the battery mixed with other different make, type, or model batteries.
- Keep out of the reach of children.
8.2 charge and discharge- Battery must be charged in appropriate charger only.
- Never use a modified or damaged charger.
- Do not leave battery in charger over 24 hours.
8.3 storage- Store the battery in a cool, dry and well-ventilated area.
8.4 disposal- Regulations vary for different countries. Dispose of in accordance with local regulations.
9. Battery operation instruction
9.1 Charging
9.1.1 Charging current:Cannot surpass the biggest charging current which in this specification book stipulated.
9.1.2 Charging voltage:Does not have to surpass the highest amount which in this specification book stipulated to decide the voltage.
9.1.3 Charge temperature:The battery must carry on the charge in the ambient temperature scope which this specification book stipulated.
9.1.4 Uses the constant electric current and the constant voltage way charge, the prohibition reverse charges. If the battery positive electrode and the cathode meet instead, can damage the battery.
9.2 Discharging
9.2.1 Discharging current The discharging current does not have to surpass this specification book stipulation the biggest discharging current, the oversized electric current electric discharge can cause the battery capacity play to reduce and to cause the battery heat.
9.2.2 discharge temperature:The battery discharge must carry on in the ambient temperature scope which this specification book stipulated
9.2.3 Over-discharges:After the short time excessively discharges charges immediately cannot affect the use, but the long time excessively discharges can cause the battery the performance, battery function losing. The battery long-term has not used, has the possibility to be able to be at because of its automatic flashover characteristic certain excessively discharges the condition, for prevented excessively discharges the occurrence, the battery should maintain the certain electric quantity.
9.3 Storing the Batteries
The battery should store in the product specification book stipulation temperature range. If has surpasses above for three months the long time storage, suggested you should carry on additional charge to the battery.
Exhibition Fair
Packaging & Shipping
Address:
1001, Building 2, Fangge Phoenix Technology Building, No. 218, Guangshen Road, Fenghuang Community, Fuyong Street, Bao′an District, Shenzhen, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, Manufacturing & Processing Machinery
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
In 2002, HK Hi-Chipcom Electronic Co., Ltd was founded.
In 2003, Our factory was founded in Shenzhen, China, which is specialize in battery.
In 2005, Hi-Chipcom applied the ISO9001; 2000 quality certificate successfully.
1n 2008, Aluminum shell battery products processing obtained the authorization of BAK.
In 2009, Production broke through 26 million.
In 2010, Production broke through 30 million.
In 2010, Hi-Chipcom set up the Quanzhou office.
In 2011, Up to 85 kinds of products obtained UL certificate.
In 2011, Hi-Chipcom passed the evaluation of Motorola, and to be the qualified supplier.
In 2012, Hi-Chipcom get bulk cooperation with Konka Group. About 100 kinds of batteries obtained the UL certificate.
In 2013, Hi-Chipcom became a qualified supplier of Hongtu High Technology Co., Ltd.
In 2014, Hi-Chipcom set up power battery R& D.
In 2015, Zhuhai manufacturing base established, production capacity of 6 million/month
In 2016, Hi-Chipcom combined with Shandong University of Technology and established research institute in Shenzhen.
In 2016, Hi-chipcom launched the new three board.